[Date Prev][Date Next][Date Index]
Re: ACS Microstepper Drives
Guy Jennings wrote:
> Just ran into a potential gotcha with the ACS SPD-3M Microstepper motor
> drive module. It is NOT a drop-in replacement for the SPD-6U
> drive!!! The SPD-3M is a bipolar drive and needs different connections
> when used with a 6-wire motor.
> Users beware!!!
I, too, did not have any trouble using the ACS microstepper as a drop-in
replacement for the ACS full/half drive.
Motors tested were Vexta PX245 and an Aerotech motor.
Pete Jemian
UNICAT